Full 3D BIM structural conversion, project-specific Eurocode static calculations, and CNC roll-former machine code driver files without material supply.
| BIM Modeling Environment: | Vertex BD / Autodesk Revit Full Level of Development (LOD 350–400) |
| Structural Static Codes: | EN 1993-1-3 (Eurocode 3), EN 1998-1 (Eurocode 8 Seismic), EN 1991 (Wind/Snow) |
| CNC Machine Outputs: | Machine-driver output files (.csv, .nc, .ord) compatible with FrameCAD, Howick, Scottsdale, Pinnacle |
| Drawing Formats: | Vector PDF 2D/3D sheets, 3D DWG/DXF panel drawings, Open BIM IFC 2x3/4 |
| Foundation Documentation: | Point load & line load reaction schedules, anchor placement blueprint with coordinate matrix |
| Bill of Materials (BOM): | Exact linear profile meters, total steel coil weight in kg, fastener count, scrap percentage |
100% Digital Delivery via Secure Cloud Portal (No Physical Freight Required)
Exempt from customs duties (Digital engineering service)
7 to 10 business days from architectural freeze
Enables immediate local CNC fabrication and error-free on-site assembly
Every component below is precision-manufactured, inspected, and accounted for in your Bill of Materials (BOM):
To maintain maximum commercial transparency and prevent budget discrepancies, the following works and materials are excluded from this specific package:
For international contractors and experienced builders, the "Structural Frame Kit" offers the highest shipping density and lowest freight cost per m². For private landowners and developers seeking a rapid building envelope, the "Weather-Tight Shell" is the optimal balance of speed, insulation performance and quality control.
Yes. While we offer standardized high-performance specifications (e.g. 150mm Rockwool + BoardeX/OSB-3 exterior sheathing + WPC/Aluminum composite siding), we can adapt thickness, density and cladding finishes to meet local energy efficiency standards (such as German KfW 40, Italian Superbonus or French RE2020 requirements).
All light gauge steel profiles are bundled with heavy-duty polyester/steel banding, wrapped in UV-resistant waterproof polyethylene film, and labeled with color-coded assembly zone tags. Containers are packed using engineered 3D loading plans to prevent transit shifting and allow sequential offloading matching the erection sequence on site.
The Engineering Only package is designed for international developers and manufacturers who possess their own roll-forming machinery or local steel sources. We provide complete 3D BIM modeling, Eurocode static calculation books, CNC machine driver output files (Vertex BD / FrameCAD compatible), and detailed assembly drawings without physical material supply.
Yes. Many clients start with a Structural Frame Kit during the initial budgetary review and subsequently upgrade to a Weather-Tight Shell once architectural window and facade specifications are finalized. All adjustments are transparently itemized prior to final manufacturing sign-off.