Made in Turkey Engineered & Manufactured in Türkiye · Delivered Worldwide
6-Layer Advanced Anatomy

6-Layer Advanced Wall Anatomy & Enclosure Physics

Engineered high-performance wall cross-section: breathable vapor-permeable membrane, exterior sheathing, dense rockwool thermal core, and internal drywall layers.

6 Layers
Engineered Composite Anatomy
220–280 mm
Total Wall Thickness
0.12–0.16
U-Value (W/m²K)
56 dB
Sound Insulation (Rw)
Envelope Physics

Multi-Layered High-Performance Thermal Wall Anatomy

Engineered wall sections incorporating non-combustible rockwool, external ETICS insulation, BoardeX sheathing, and smart vapor retarders.

01

Exterior Breathable Barrier & Moisture Management

A micro-perforated weather-resistant membrane lets interior water vapor escape outward while completely blocking external wind-driven rain, eliminating condensation and mold risk.

02

Dense Cavity Rockwool Core (50–70 kg/m³)

Hydrophobic basalt mineral wool fills the entire 90–140mm stud cavity, providing continuous A1 non-combustible fire protection, outstanding thermal resistance, and acoustic dampening.

03

External Thermal Envelope (EIFS / ETICS)

Continuous 50–100mm exterior EPS/mineral wool insulation wraps around the steel framing, moving the thermal dew point safely to the outside and eliminating all steel thermal bridges.

Technology Chapters

Explore Related Engineering Topics

Dive deeper into other facets of our cold-formed steel manufacturing, wall systems, and energy physics.

S350GD+Z275 · EN 10346

Light Gauge Steel Framing & Metallurgy Science

High-yield S350GD structural steel with 275 g/m² hot-dip zinc coating. CNC roll-formed to sub-millimeter tolerances with 50+ year anti-corrosion protection.

Explore Topic
Engineered Trusses & Floor Joists

Engineered Roof Trusses, Rafters & Structural Floor Cassettes

Clear-span roof trusses up to 12+ meters without intermediate columns. Engineered floor joists designed for zero vibration and deflection limits of L/500.

Explore Topic
Passivhaus · RE2020 · GEG 2024

Thermal Performance, Passivhaus Physics & Zero Energy Bills

Eliminate thermal bridges with continuous external insulation (U-values: 0.12–0.16 W/m²K). Comply with Germany's GEG 2024, France's RE2020, and Swiss Minergie standards.

Explore Topic
Eurocode 8 · High Seismic Ductility

Eurocode 8 Earthquake Resistance & Structural Safety

Lightweight structural physics meets high ductility. Superior seismic behavior factor (q ≥ 3.0), zero brittle masonry collapse risk, and certified safety for high seismic zones (PGA ≥ 0.40g).

Explore Topic
REI 60/90/120 · Rw ≥ 56 dB

Acoustic Soundproofing & Certified Fire Safety (REI 120)

Total acoustic tranquility (Rw ≥ 56 dB) through mass-spring-mass physics. Certified A1 non-combustible rockwool cores providing REI 60, 90, and 120 fire resistance ratings.

Explore Topic
Eurocode 2/7 · Slab & Anchors

Foundation Systems, Slab Engineering & Seismic Ground Anchors

Up to 40% reduction in concrete slab volume due to lower superstructure mass. Compatible with reinforced rafts, strip footings, crawl spaces, and screw-pile foundations for steep terrain.

Explore Topic
Z275 Galvanization · C4/C5 Rating

Galvanic Cathodic Corrosion Protection & Coastal Durability

How continuous Z275 hot-dip zinc coating provides sacrificial cathodic self-healing protection, achieving 100+ years of structural integrity across harsh marine (C4/C5), alpine, and high-humidity climates.

Explore Topic
Pre-Punched MEP · Smart Home Ready

Pre-Engineered MEP Service Chaseways & Smart Villa Infrastructure

Precision factory-punched service chaseways in steel studs and floor joists for electrical conduits, PEX plumbing, MVHR ducts, and central home automation with zero on-site drilling.

Explore Topic
U ≤ 0.11 · REI 60–120 · Rw 54–62 dB

Building Assemblies, Technical Cross-Sections & U-Values

Certified structural layer stratigraphies, thermal transmittance (U-values down to 0.11 W/m²K), acoustic soundproofing (Rw up to 62 dB), and REI 60–120 fire ratings.

Explore Topic
Frequently Asked Questions

Technical Questions & Scientific Evidence

Clear engineering answers regarding this material and physics topic.

Yes. Our factory inserts 1.5mm galvanized steel backing plates (nogging) behind planned cabinet locations during manufacturing, or heavy-duty cavity anchors can be fixed directly into the C-studs supporting up to 120 kg per fixing point.

Our wall system uses an outward vapor-permeable design: an internal airtight vapor barrier prevents indoor moisture from entering the wall cavity, while the breathable exterior BoardeX/Tyvek layer allows any residual moisture to escape freely without condensation.

Virtually any architectural finish: silicone/acrylic ETICS render, natural stone or ceramic tile veneer, ventilated timber or composite cladding (Trespa, Alucobond), and clinker brick slips, all directly secured to the outer sheathing or subframe.

Ready to Engineer Your High-Performance Steel Frame Villa?

Submit your architectural project for a complimentary Eurocode structural feasibility check and indicative cost estimate.