Made in Turkey Engineered & Manufactured in Türkiye · Delivered Worldwide
Itemized Fasteners & Hardware

Itemized Bill of Materials (BOM) & Fastener Hardware Schedules

Every single profile, structural screw, chemical anchor, hold-down bracket, and sheathing board is itemized with precise quantities, weights, and EN 10204 3.1 batch certifications.

100%
Itemized Fasteners & Hardware
+10%
Spare Hardware Included in Kit
EN 10204
3.1 Steel Coil Certificates
±0 kg
Container Weight Audit Precision
Material Audit

Itemized Bill of Materials & Fastener Quantification

Every single stud, track, gusset plate, anchor bolt, and structural self-drilling screw quantified straight from the 3D model.

01

Complete Linear Profile Meterage & Weight Summary

The BOM details every gauge (0.90mm to 2.00mm), C-stud width (90mm, 140mm), and U-track linear meterage, providing complete structural weight breakdown for transport planning.

02

Certified Structural Hardware & Fastener Callouts

Self-drilling hex-head screws with Ruspert 1000-hour salt-spray anti-corrosion coating, hold-down brackets, shear angles, and M16 chemical capsules are quantified with +10% site contingency.

03

Container Manifest & Phase-Coded Packing Matrix

The BOM links directly to the shipping container manifest, indicating which specific bundle number contains the ground floor tracks, wall studs, and roof trusses for rapid site staging.

Engineering Hub

Explore Related Engineering Documentation

Dive deeper into our Eurocode static calculations, 3D assembly plans, BOM schedules, and municipality permit assistance.

Eurocode 1/3/8 Harmonized

Eurocode Structural Static Calculations & Finite Element Analysis

Full structural calculation dossiers verified strictly according to EN 1990, EN 1991 (Wind/Snow), EN 1993-1-3 (Cold-Formed Steel), and EN 1998 (Seismic). Ready for municipal stamping.

Explore Topic
3D Visual Assembly Manuals

3D Step-by-Step Assembly Manuals & Erection Blueprints

Millimeter-exact 3D isometric assembly blueprints. Every panel, truss, and stud is color-coded and numbered matching the automated inkjet markings printed on the steel.

Explore Topic
Interactive Engineering Dossier

Sample Engineering Package & Technical Dossier Download

Review a complete sample engineering deliverable pack for a 2-storey luxury steel frame villa: Eurocode static calculation excerpt, 3D assembly manual pages, foundation reaction schedule, and BOM.

Explore Topic
Revit · Vertex BD · Tekla · IFC

3D Parametric BIM Pipeline & CNC Machine Code Integration

From architectural concept to factory floor with zero translation errors. Automated clash detection, MEP service chaseways, and direct NC export to multi-axis roll-formers.

Explore Topic
Slab Reactions & Anchor Schedules

Foundation Reaction Schedules & Anchor Coordinate Plans

Exact point loads, continuous line loads (kN/m), overturning moment reactions, and anchor bolt positioning coordinates delivered 3–4 weeks prior to steel shipment.

Explore Topic
European Permitting Desk

European Building Permits & Municipality Compliance Coordination

Streamline your planning approval across Germany (Bauantrag), Italy (Permesso di Costruire/SCIA), France (Permis de Construire), the UK, and Greece with our multilingual engineering desk.

Explore Topic
Bespoke Conversion · DWG / PDF / IFC

Custom Architectural CAD-to-Steel Structural Conversion

Already have architectural drawings from your local architect? Our structural engineering department converts your bespoke DWG, PDF, or IFC blueprints into Eurocode-compliant cold-formed steel frames with zero compromise to your architectural vision.

Explore Topic
EN 1991-1-4 · EN 1998-1

Extreme Wind Velocity & High Seismic Load Engineering

Engineered for extreme coastal hurricane gusts (up to 250 km/h), high Alpine snow accumulations (≥ 3.5 kN/m²), and high seismic ground accelerations (PGA ≥ 0.40g) across Europe.

Explore Topic
Frequently Asked Questions

Technical Questions & Engineering Clarifications

Clear technical answers regarding calculations, drawings, and regulatory submission.

Yes. Every delivery package includes 100% of the structural self-drilling screws, expansion anchor bolts, hold-down brackets, and specialized driver bits needed for complete structural erection, including +10% spare hardware.

Yes. Every hardware kit includes a calibrated +10% contingency buffer for structural self-drilling screws, expansion anchors, driver bits, and angle brackets to ensure seamless jobsite progress without supply interruptions.

Materials are bundled in chronological erection order: ground floor tracks and load-bearing wall studs on top/front for immediate unloading, followed by intermediate floor cassettes, roof trusses, and sheathing boards, all banded with crane lifting loops.

Request a Sample Engineering Package or Submit Your Project Blueprints

Upload your architectural drawings (PDF/DWG/IFC) to receive a structural feasibility evaluation, foundation interface loads, and manufacturing cost schedule.