Made in Turkey Engineered & Manufactured in Türkiye · Delivered Worldwide
Slab Reactions & Anchor Schedules

Foundation Reaction Schedules & Anchor Coordinate Plans

Exact point loads, continuous line loads (kN/m), overturning moment reactions, and anchor bolt positioning coordinates delivered 3–4 weeks prior to steel shipment.

3–4 Wks
Prior Delivery to Local Concrete Team
kN / m
Exact Line & Point Load Data
±0 mm
Anchor Bolt Positioning Grid
40 kN+
Hold-Down Uplift Capacity Verified
Structural Interfaces

Point & Line Reactions for Foundation Engineers

Accurate axial, shear, and uplift reaction schedules delivered early to optimize reinforced concrete slab design.

01

Early Foundation Schedule Delivery for Groundwork Contractors

While steel framing is roll-formed in our Gebze factory, your local groundwork contractor receives full foundation reaction diagrams, enabling slab casting and curing without project delays.

02

Itemized Vertical, Horizontal & Moment Reaction Matrix

Every shear wall connection node is documented with Dead (G), Live (Q), Wind (W), and Seismic (E) load combinations, providing local civil engineers with exact data for slab reinforcement design.

03

Slab Edge Rebate & Waterproofing Interface Details

Clear architectural detail drawings indicate the required perimeter slab rebate (e.g. 50x50mm recess), DPC bitumen moisture barriers, and thermal insulation upstands.

Engineering Hub

Explore Related Engineering Documentation

Dive deeper into our Eurocode static calculations, 3D assembly plans, BOM schedules, and municipality permit assistance.

Eurocode 1/3/8 Harmonized

Eurocode Structural Static Calculations & Finite Element Analysis

Full structural calculation dossiers verified strictly according to EN 1990, EN 1991 (Wind/Snow), EN 1993-1-3 (Cold-Formed Steel), and EN 1998 (Seismic). Ready for municipal stamping.

Explore Topic
3D Visual Assembly Manuals

3D Step-by-Step Assembly Manuals & Erection Blueprints

Millimeter-exact 3D isometric assembly blueprints. Every panel, truss, and stud is color-coded and numbered matching the automated inkjet markings printed on the steel.

Explore Topic
Itemized Fasteners & Hardware

Itemized Bill of Materials (BOM) & Fastener Hardware Schedules

Every single profile, structural screw, chemical anchor, hold-down bracket, and sheathing board is itemized with precise quantities, weights, and EN 10204 3.1 batch certifications.

Explore Topic
Interactive Engineering Dossier

Sample Engineering Package & Technical Dossier Download

Review a complete sample engineering deliverable pack for a 2-storey luxury steel frame villa: Eurocode static calculation excerpt, 3D assembly manual pages, foundation reaction schedule, and BOM.

Explore Topic
Revit · Vertex BD · Tekla · IFC

3D Parametric BIM Pipeline & CNC Machine Code Integration

From architectural concept to factory floor with zero translation errors. Automated clash detection, MEP service chaseways, and direct NC export to multi-axis roll-formers.

Explore Topic
European Permitting Desk

European Building Permits & Municipality Compliance Coordination

Streamline your planning approval across Germany (Bauantrag), Italy (Permesso di Costruire/SCIA), France (Permis de Construire), the UK, and Greece with our multilingual engineering desk.

Explore Topic
Bespoke Conversion · DWG / PDF / IFC

Custom Architectural CAD-to-Steel Structural Conversion

Already have architectural drawings from your local architect? Our structural engineering department converts your bespoke DWG, PDF, or IFC blueprints into Eurocode-compliant cold-formed steel frames with zero compromise to your architectural vision.

Explore Topic
EN 1991-1-4 · EN 1998-1

Extreme Wind Velocity & High Seismic Load Engineering

Engineered for extreme coastal hurricane gusts (up to 250 km/h), high Alpine snow accumulations (≥ 3.5 kN/m²), and high seismic ground accelerations (PGA ≥ 0.40g) across Europe.

Explore Topic
Frequently Asked Questions

Technical Questions & Engineering Clarifications

Clear technical answers regarding calculations, drawings, and regulatory submission.

We supply 100% of the superstructure reaction loads, anchor coordinates, and perimeter slab geometry. Your local licensed civil engineer designs the internal concrete rebar reinforcement calibrated to your local soil bearing capacity report.

The blueprint provides exact point loads (vertical compression & uplift tension in kN), continuous distributed wall line loads (kN/m), overturning moment vectors, and millimeter-precise anchor bolt drill coordinates.

We specify and supply CE-certified M12/M16 heavy-duty chemical injection anchors (Hilti/Fischer equivalent) or mechanical expansion anchor bolts along with Simpson Strong-Tie seismic hold-down brackets rated for design uplift forces.

Request a Sample Engineering Package or Submit Your Project Blueprints

Upload your architectural drawings (PDF/DWG/IFC) to receive a structural feasibility evaluation, foundation interface loads, and manufacturing cost schedule.