Made in Turkey Engineered & Manufactured in Türkiye · Delivered Worldwide
EN 1991-1-4 · EN 1998-1

Extreme Wind Velocity & High Seismic Load Engineering

Engineered for extreme coastal hurricane gusts (up to 250 km/h), high Alpine snow accumulations (≥ 3.5 kN/m²), and high seismic ground accelerations (PGA ≥ 0.40g) across Europe.

≤ 250 km/h
Hurricane-Force Wind Resistance
PGA ≥ 0.40g
Peak Ground Acceleration (Seismic)
≥ 3.5 kN/m²
Heavy Alpine Snow Load Rating
0 Failure
20+ Year Global Structural Track Record
Engineering Deliverables

Technical Standards & Execution Protocols

Detailed technical breakdowns, structural calculations, and practical jobsite execution recommendations.

01

Aerodynamic Wind Pressure & Uplift Analysis (EN 1991-1-4)

On exposed coastal cliffs in Greece, Italy, France, and the UK, wind creates massive upward suction on roofs. We engineer continuous uplift straps and reinforced rafter-to-wall ties.

02

Heavy Alpine Snow Accumulation Trusses (EN 1991-1-3)

For Alpine chalets in Switzerland, Austria, and Germany, roof trusses are engineered with heavy gauge web members and close 400mm centers to withstand deep snow drifts exceeding 350 kg/m².

03

Ductile Seismic Diaphragms & Foundation Uplift Anchors

High-strength shear wall sheathing (BoardeX / OSB-3) acts as a structural diaphragm, absorbing lateral ground shaking and transferring kinetic energy into foundation hold-downs without structural damage.

Engineering Hub

Explore Related Engineering Documentation

Dive deeper into our Eurocode static calculations, 3D assembly plans, BOM schedules, and municipality permit assistance.

Eurocode 1/3/8 Harmonized

Eurocode Structural Static Calculations & Finite Element Analysis

Full structural calculation dossiers verified strictly according to EN 1990, EN 1991 (Wind/Snow), EN 1993-1-3 (Cold-Formed Steel), and EN 1998 (Seismic). Ready for municipal stamping.

Explore Topic
3D Visual Assembly Manuals

3D Step-by-Step Assembly Manuals & Erection Blueprints

Millimeter-exact 3D isometric assembly blueprints. Every panel, truss, and stud is color-coded and numbered matching the automated inkjet markings printed on the steel.

Explore Topic
Itemized Fasteners & Hardware

Itemized Bill of Materials (BOM) & Fastener Hardware Schedules

Every single profile, structural screw, chemical anchor, hold-down bracket, and sheathing board is itemized with precise quantities, weights, and EN 10204 3.1 batch certifications.

Explore Topic
Interactive Engineering Dossier

Sample Engineering Package & Technical Dossier Download

Review a complete sample engineering deliverable pack for a 2-storey luxury steel frame villa: Eurocode static calculation excerpt, 3D assembly manual pages, foundation reaction schedule, and BOM.

Explore Topic
Revit · Vertex BD · Tekla · IFC

3D Parametric BIM Pipeline & CNC Machine Code Integration

From architectural concept to factory floor with zero translation errors. Automated clash detection, MEP service chaseways, and direct NC export to multi-axis roll-formers.

Explore Topic
Slab Reactions & Anchor Schedules

Foundation Reaction Schedules & Anchor Coordinate Plans

Exact point loads, continuous line loads (kN/m), overturning moment reactions, and anchor bolt positioning coordinates delivered 3–4 weeks prior to steel shipment.

Explore Topic
European Permitting Desk

European Building Permits & Municipality Compliance Coordination

Streamline your planning approval across Germany (Bauantrag), Italy (Permesso di Costruire/SCIA), France (Permis de Construire), the UK, and Greece with our multilingual engineering desk.

Explore Topic
Bespoke Conversion · DWG / PDF / IFC

Custom Architectural CAD-to-Steel Structural Conversion

Already have architectural drawings from your local architect? Our structural engineering department converts your bespoke DWG, PDF, or IFC blueprints into Eurocode-compliant cold-formed steel frames with zero compromise to your architectural vision.

Explore Topic
Frequently Asked Questions

Technical Questions & Engineering Clarifications

Clear technical answers regarding calculations, drawings, and regulatory submission.

Yes. Throughout 20+ years across active earthquake zones in Türkiye, Greece, and Italy (including major Richter 7.0+ seismic events), zero SerVilla steel frame villas have experienced structural collapse or life-threatening damage.

Framing assemblies undergo static and dynamic wind pressure verification according to Eurocode 1 (EN 1991-1-4) simulating gust pressures over 250 km/h, verified with continuous strap cross-bracing, Simpson hold-downs, and diaphragm sheathing tests.

Every production batch is backed by official EN 10204 Type 3.1 Inspection Mill Certificates verifying chemical composition, yield strength (fy ≥ 350 MPa), tensile strength, elongation at break, and continuous hot-dip zinc coating thickness (Z275).

Request a Sample Engineering Package or Submit Your Project Blueprints

Upload your architectural drawings (PDF/DWG/IFC) to receive a structural feasibility evaluation, foundation interface loads, and manufacturing cost schedule.