Made in Turkey Engineered & Manufactured in Türkiye · Delivered Worldwide
REI 60/90/120 · Rw ≥ 56 dB

Acoustic Soundproofing & Certified Fire Safety (REI 120)

Total acoustic tranquility (Rw ≥ 56 dB) through mass-spring-mass physics. Certified A1 non-combustible rockwool cores providing REI 60, 90, and 120 fire resistance ratings.

Rw ≥ 56 dB
Sound Insulation Rating
REI 120
Fire Resistance Classification
Euroclass A1
Non-Combustible Insulation Core
0 Toxicity
Zero Toxic Smoke Emissions
Acoustics & Fire

REI 60–120 Fire Resistance & 56+ dB Acoustic Soundproofing

Class A1 non-combustible rockwool cores, fire-rated BoardeX claddings, and decoupled acoustic stud channels for ultimate comfort.

01

Mass-Spring-Mass Acoustic Physics

By sandwiching absorbing rockwool (the spring) between dense exterior sheathing and double interior drywalls (the masses), sound waves lose kinetic energy, outperforming heavy solid brick walls.

02

Certified REI 60, 90 & 120 Passive Fire Protection

Steel is non-combustible and does not feed flames. Shielded by fire-rated Type F gypsum boards and rockwool, the structure maintains load-bearing stability for up to 120 minutes in a fire.

03

Resilient Sound Isolation Channels for Partitions

Interior bedroom and home office partition walls utilize acoustic decoupling strips and staggered stud cavities to achieve whisper-quiet living spaces below 35 dB background noise.

Technology Chapters

Explore Related Engineering Topics

Dive deeper into other facets of our cold-formed steel manufacturing, wall systems, and energy physics.

S350GD+Z275 · EN 10346

Light Gauge Steel Framing & Metallurgy Science

High-yield S350GD structural steel with 275 g/m² hot-dip zinc coating. CNC roll-formed to sub-millimeter tolerances with 50+ year anti-corrosion protection.

Explore Topic
6-Layer Advanced Anatomy

6-Layer Advanced Wall Anatomy & Enclosure Physics

Engineered high-performance wall cross-section: breathable vapor-permeable membrane, exterior sheathing, dense rockwool thermal core, and internal drywall layers.

Explore Topic
Engineered Trusses & Floor Joists

Engineered Roof Trusses, Rafters & Structural Floor Cassettes

Clear-span roof trusses up to 12+ meters without intermediate columns. Engineered floor joists designed for zero vibration and deflection limits of L/500.

Explore Topic
Passivhaus · RE2020 · GEG 2024

Thermal Performance, Passivhaus Physics & Zero Energy Bills

Eliminate thermal bridges with continuous external insulation (U-values: 0.12–0.16 W/m²K). Comply with Germany's GEG 2024, France's RE2020, and Swiss Minergie standards.

Explore Topic
Eurocode 8 · High Seismic Ductility

Eurocode 8 Earthquake Resistance & Structural Safety

Lightweight structural physics meets high ductility. Superior seismic behavior factor (q ≥ 3.0), zero brittle masonry collapse risk, and certified safety for high seismic zones (PGA ≥ 0.40g).

Explore Topic
Eurocode 2/7 · Slab & Anchors

Foundation Systems, Slab Engineering & Seismic Ground Anchors

Up to 40% reduction in concrete slab volume due to lower superstructure mass. Compatible with reinforced rafts, strip footings, crawl spaces, and screw-pile foundations for steep terrain.

Explore Topic
Z275 Galvanization · C4/C5 Rating

Galvanic Cathodic Corrosion Protection & Coastal Durability

How continuous Z275 hot-dip zinc coating provides sacrificial cathodic self-healing protection, achieving 100+ years of structural integrity across harsh marine (C4/C5), alpine, and high-humidity climates.

Explore Topic
Pre-Punched MEP · Smart Home Ready

Pre-Engineered MEP Service Chaseways & Smart Villa Infrastructure

Precision factory-punched service chaseways in steel studs and floor joists for electrical conduits, PEX plumbing, MVHR ducts, and central home automation with zero on-site drilling.

Explore Topic
U ≤ 0.11 · REI 60–120 · Rw 54–62 dB

Building Assemblies, Technical Cross-Sections & U-Values

Certified structural layer stratigraphies, thermal transmittance (U-values down to 0.11 W/m²K), acoustic soundproofing (Rw up to 62 dB), and REI 60–120 fire ratings.

Explore Topic
Frequently Asked Questions

Technical Questions & Scientific Evidence

Clear engineering answers regarding this material and physics topic.

Yes. With certified REI 60 to REI 120 fire barrier assemblies, our system meets and exceeds all European national fire codes for residential and commercial multi-storey construction.

Our standard exterior and party wall assemblies achieve REI 60 to REI 120 fire resistance ratings (EN 13501-2). Galvanized steel is Class A1 non-combustible, and non-flammable rockwool cores combined with Type F fire-resistant drywall prevent flame spread.

Through mass-spring-mass acoustic engineering: acoustic decoupling resilient channels, high-density mineral wool cavity baffles, and double drywall layers achieve airborne sound reduction of Rw = 54–62 dB for walls and impact sound Ln,w ≤ 48 dB for floors.

Ready to Engineer Your High-Performance Steel Frame Villa?

Submit your architectural project for a complimentary Eurocode structural feasibility check and indicative cost estimate.