Precision factory-punched service chaseways in steel studs and floor joists for electrical conduits, PEX plumbing, MVHR ducts, and central home automation with zero on-site drilling.
Factory-punched service routing holes in every stud for rapid electrical wiring, plumbing, HVAC heat pumps, and home automation.
Every vertical stud and horizontal joist features factory-punched flared service holes at calibrated heights, allowing electricians and network technicians to pull kilometers of conduit in hours with protective nylon grommets.
Flexible multi-layer PEX-a water supply lines route effortlessly through stud cavities. Waste stacks are wrapped in acoustic mineral wool damping sleeves inside internal partitions, delivering whisper-quiet drainage performance.
Open-web floor lattice joists and suspended ceiling zones accommodate 75mm–125mm semi-rigid MVHR heat recovery ducts, smart lighting bus cables (KNX/DALI), and integrated audio wiring with zero drop-ceilings.
Dive deeper into other facets of our cold-formed steel manufacturing, wall systems, and energy physics.
High-yield S350GD structural steel with 275 g/m² hot-dip zinc coating. CNC roll-formed to sub-millimeter tolerances with 50+ year anti-corrosion protection.
Explore TopicEngineered high-performance wall cross-section: breathable vapor-permeable membrane, exterior sheathing, dense rockwool thermal core, and internal drywall layers.
Explore TopicClear-span roof trusses up to 12+ meters without intermediate columns. Engineered floor joists designed for zero vibration and deflection limits of L/500.
Explore TopicEliminate thermal bridges with continuous external insulation (U-values: 0.12–0.16 W/m²K). Comply with Germany's GEG 2024, France's RE2020, and Swiss Minergie standards.
Explore TopicLightweight structural physics meets high ductility. Superior seismic behavior factor (q ≥ 3.0), zero brittle masonry collapse risk, and certified safety for high seismic zones (PGA ≥ 0.40g).
Explore TopicTotal acoustic tranquility (Rw ≥ 56 dB) through mass-spring-mass physics. Certified A1 non-combustible rockwool cores providing REI 60, 90, and 120 fire resistance ratings.
Explore TopicUp to 40% reduction in concrete slab volume due to lower superstructure mass. Compatible with reinforced rafts, strip footings, crawl spaces, and screw-pile foundations for steep terrain.
Explore TopicHow continuous Z275 hot-dip zinc coating provides sacrificial cathodic self-healing protection, achieving 100+ years of structural integrity across harsh marine (C4/C5), alpine, and high-humidity climates.
Explore TopicCertified structural layer stratigraphies, thermal transmittance (U-values down to 0.11 W/m²K), acoustic soundproofing (Rw up to 62 dB), and REI 60–120 fire ratings.
Explore TopicClear engineering answers regarding this material and physics topic.
No. Because all service chaseways are pre-punched at the factory with standard 34mm/50mm diameters, tradesmen simply insert standard plastic snap-in grommets and pull standard corrugated conduits and PEX pipes. No concrete chasing, no masonry grinders, and no structural drilling required.
During CNC roll-forming in our factory, flared 34mm service grommet pass-through holes are punched automatically at calibrated heights according to the 3D BIM model, allowing fast, snag-free cable and PEX pipe pulling on site.
Yes. Pre-engineered cavity wall chaseways accommodate centralized KNX/Loxone bus cables, concealed smart climate sensors, ducted heat recovery ventilation (MVHR), motorized shading, and smart inverter heat pumps seamlessly.
Submit your architectural project for a complimentary Eurocode structural feasibility check and indicative cost estimate.