Made in Turkey Engineered & Manufactured in Türkiye · Delivered Worldwide
Engineered Trusses & Floor Joists

Engineered Roof Trusses, Rafters & Structural Floor Cassettes

Clear-span roof trusses up to 12+ meters without intermediate columns. Engineered floor joists designed for zero vibration and deflection limits of L/500.

12+ m
Column-Free Clear Span
L / 500
Floor Deflection Standard
≥ 3.5 kN/m²
Snow Load Capacity (Alpine)
100% CAD
CNC Pre-Engineered Truss Nodes
Roof Engineering

Engineered Truss Geometry, Snow Load Capacity & Water Ingress Defense

Engineered for flat green roofs, modern monopitches, and traditional gable roofs with extreme alpine snow resistance (up to 4.5 kN/m²).

01

Column-Free Architectural Freedom (12m+ Spans)

Engineered triangulated lattice steel trusses easily bridge open-plan living rooms, double-height voids, and wide terrace overhangs without unsightly intermediate structural columns.

02

Acoustically Decoupled Stiff Floor Joists

Deep C-joists or lattice joists combined with acoustic damping strips and resilient channels eliminate the springy, creaky feel of traditional timber floors.

03

Universal Roof Covering Compatibility

SerVilla roof frames natively support standing seam aluminum/zinc sheets, concrete/ceramic tiles, EPDM flat roof waterproof membranes, and extensive green roof vegetation.

Technology Chapters

Explore Related Engineering Topics

Dive deeper into other facets of our cold-formed steel manufacturing, wall systems, and energy physics.

S350GD+Z275 · EN 10346

Light Gauge Steel Framing & Metallurgy Science

High-yield S350GD structural steel with 275 g/m² hot-dip zinc coating. CNC roll-formed to sub-millimeter tolerances with 50+ year anti-corrosion protection.

Explore Topic
6-Layer Advanced Anatomy

6-Layer Advanced Wall Anatomy & Enclosure Physics

Engineered high-performance wall cross-section: breathable vapor-permeable membrane, exterior sheathing, dense rockwool thermal core, and internal drywall layers.

Explore Topic
Passivhaus · RE2020 · GEG 2024

Thermal Performance, Passivhaus Physics & Zero Energy Bills

Eliminate thermal bridges with continuous external insulation (U-values: 0.12–0.16 W/m²K). Comply with Germany's GEG 2024, France's RE2020, and Swiss Minergie standards.

Explore Topic
Eurocode 8 · High Seismic Ductility

Eurocode 8 Earthquake Resistance & Structural Safety

Lightweight structural physics meets high ductility. Superior seismic behavior factor (q ≥ 3.0), zero brittle masonry collapse risk, and certified safety for high seismic zones (PGA ≥ 0.40g).

Explore Topic
REI 60/90/120 · Rw ≥ 56 dB

Acoustic Soundproofing & Certified Fire Safety (REI 120)

Total acoustic tranquility (Rw ≥ 56 dB) through mass-spring-mass physics. Certified A1 non-combustible rockwool cores providing REI 60, 90, and 120 fire resistance ratings.

Explore Topic
Eurocode 2/7 · Slab & Anchors

Foundation Systems, Slab Engineering & Seismic Ground Anchors

Up to 40% reduction in concrete slab volume due to lower superstructure mass. Compatible with reinforced rafts, strip footings, crawl spaces, and screw-pile foundations for steep terrain.

Explore Topic
Z275 Galvanization · C4/C5 Rating

Galvanic Cathodic Corrosion Protection & Coastal Durability

How continuous Z275 hot-dip zinc coating provides sacrificial cathodic self-healing protection, achieving 100+ years of structural integrity across harsh marine (C4/C5), alpine, and high-humidity climates.

Explore Topic
Pre-Punched MEP · Smart Home Ready

Pre-Engineered MEP Service Chaseways & Smart Villa Infrastructure

Precision factory-punched service chaseways in steel studs and floor joists for electrical conduits, PEX plumbing, MVHR ducts, and central home automation with zero on-site drilling.

Explore Topic
U ≤ 0.11 · REI 60–120 · Rw 54–62 dB

Building Assemblies, Technical Cross-Sections & U-Values

Certified structural layer stratigraphies, thermal transmittance (U-values down to 0.11 W/m²K), acoustic soundproofing (Rw up to 62 dB), and REI 60–120 fire ratings.

Explore Topic
Frequently Asked Questions

Technical Questions & Scientific Evidence

Clear engineering answers regarding this material and physics topic.

Yes. During 3D engineering, we incorporate the additional dead load and wind uplift of rooftop PV solar arrays into the static model, ensuring certified mounting brackets clamp directly to the steel purlins.

Yes. Every roof structure is customized in 3D FEM software to Eurocode 1 (EN 1991-1-3) national annexes, accommodating extreme alpine snow loads up to 4.5 kN/m² through optimized truss triangulation and heavy-gauge steel chord profiles.

Our roof framing supports all European roofing types: standing seam zinc/aluminum metal sheets, traditional clay or concrete tiles, slate, flat roof EPDM/PVC waterproofing membranes, and integrated solar PV panel arrays.

Ready to Engineer Your High-Performance Steel Frame Villa?

Submit your architectural project for a complimentary Eurocode structural feasibility check and indicative cost estimate.