Made in Turkey Engineered & Manufactured in Türkiye · Delivered Worldwide
Passivhaus · RE2020 · GEG 2024

Thermal Performance, Passivhaus Physics & Zero Energy Bills

Eliminate thermal bridges with continuous external insulation (U-values: 0.12–0.16 W/m²K). Comply with Germany's GEG 2024, France's RE2020, and Swiss Minergie standards.

0.12 W/m²K
Ultra-Low Wall U-Value
0.08 W/m²K
Roof Thermal Transmittance
0 Kältebrücke
Thermal Bridges Eliminated
-60%
Heating & Cooling Energy Demand
Thermal Physics

Thermal Bridge-Free Envelopes & Passivhaus U-Values (U ≤ 0.12 W/m²K)

How continuous exterior insulation, airtight membrane taping, and triple glazing eliminate thermal bridging and cut heating loads by up to 70%.

01

Continuous Exterior Wrap Thermal Break

By wrapping the exterior of the steel frame with dense continuous insulation boards (ETICS), the steel studs are kept completely within the heated thermal envelope, preventing thermal bridging.

02

Triple-Glazed Argon Low-E Window Integration

Factory-coordinated window openings receive German multi-chamber PVC or thermal-break aluminum profiles with Uw ≤ 0.80 W/m²K and warm-edge spacers for airtight sealing.

03

Airtight Building Envelope & Heat Recovery Ventilation

Taped vapor barrier membranes achieve airtightness values n50 ≤ 0.60 h⁻¹, perfect for pairing with mechanical heat recovery ventilation (MVHR) that recovers 90%+ of indoor warmth.

Technology Chapters

Explore Related Engineering Topics

Dive deeper into other facets of our cold-formed steel manufacturing, wall systems, and energy physics.

S350GD+Z275 · EN 10346

Light Gauge Steel Framing & Metallurgy Science

High-yield S350GD structural steel with 275 g/m² hot-dip zinc coating. CNC roll-formed to sub-millimeter tolerances with 50+ year anti-corrosion protection.

Explore Topic
6-Layer Advanced Anatomy

6-Layer Advanced Wall Anatomy & Enclosure Physics

Engineered high-performance wall cross-section: breathable vapor-permeable membrane, exterior sheathing, dense rockwool thermal core, and internal drywall layers.

Explore Topic
Engineered Trusses & Floor Joists

Engineered Roof Trusses, Rafters & Structural Floor Cassettes

Clear-span roof trusses up to 12+ meters without intermediate columns. Engineered floor joists designed for zero vibration and deflection limits of L/500.

Explore Topic
Eurocode 8 · High Seismic Ductility

Eurocode 8 Earthquake Resistance & Structural Safety

Lightweight structural physics meets high ductility. Superior seismic behavior factor (q ≥ 3.0), zero brittle masonry collapse risk, and certified safety for high seismic zones (PGA ≥ 0.40g).

Explore Topic
REI 60/90/120 · Rw ≥ 56 dB

Acoustic Soundproofing & Certified Fire Safety (REI 120)

Total acoustic tranquility (Rw ≥ 56 dB) through mass-spring-mass physics. Certified A1 non-combustible rockwool cores providing REI 60, 90, and 120 fire resistance ratings.

Explore Topic
Eurocode 2/7 · Slab & Anchors

Foundation Systems, Slab Engineering & Seismic Ground Anchors

Up to 40% reduction in concrete slab volume due to lower superstructure mass. Compatible with reinforced rafts, strip footings, crawl spaces, and screw-pile foundations for steep terrain.

Explore Topic
Z275 Galvanization · C4/C5 Rating

Galvanic Cathodic Corrosion Protection & Coastal Durability

How continuous Z275 hot-dip zinc coating provides sacrificial cathodic self-healing protection, achieving 100+ years of structural integrity across harsh marine (C4/C5), alpine, and high-humidity climates.

Explore Topic
Pre-Punched MEP · Smart Home Ready

Pre-Engineered MEP Service Chaseways & Smart Villa Infrastructure

Precision factory-punched service chaseways in steel studs and floor joists for electrical conduits, PEX plumbing, MVHR ducts, and central home automation with zero on-site drilling.

Explore Topic
U ≤ 0.11 · REI 60–120 · Rw 54–62 dB

Building Assemblies, Technical Cross-Sections & U-Values

Certified structural layer stratigraphies, thermal transmittance (U-values down to 0.11 W/m²K), acoustic soundproofing (Rw up to 62 dB), and REI 60–120 fire ratings.

Explore Topic
Frequently Asked Questions

Technical Questions & Scientific Evidence

Clear engineering answers regarding this material and physics topic.

Yes. High-density rockwool insulation and exterior ETICS provide substantial thermal phase shift (decrement delay > 10 hours), stopping daytime solar heat from penetrating indoors.

Cold bridging is completely eliminated through a continuous external thermal break layer: 50mm to 100mm of high-density rockwool or EPS wraps the exterior steel frame entirely, isolating the metal skeleton from outside temperature swings.

Yes. With overall wall U-values as low as 0.12 W/m²K, roof U-values of 0.10 W/m²K, airtight envelope detailing, and triple-glazed Low-E windows, our buildings easily meet Passivhaus, German KfW 40, and French RE2020 benchmarks.

Ready to Engineer Your High-Performance Steel Frame Villa?

Submit your architectural project for a complimentary Eurocode structural feasibility check and indicative cost estimate.